Files with extensions .rec and .hyp contain original recordings and their hypnograms, respectively, in European Data Format. EDF is specified in
B Kemp, A Värri, AC Rosa, KD Nielsen, J Gade. A simple format for exchange of digitized polygraphic recordings. Electroencephalography and Clinical Neurophysiology 82:391-393 (1992).More about EDF is on www.edfplus.info. Each EDF file has a header specifying patient, recording and signals including their calibration. Converters to (and from) WFDB native format are included in the WFDB Software Package (see edf2mit(1) in the WFDB Applications Guide). Applications using WFDB library version 10.4.5 or later can read EDF files directly with no conversion required.
The recordings were obtained from Caucasian males and females (21 - 35 years old) without any medication; they contain horizontal EOG, FpzCz and PzOz EEG, each sampled at 100 Hz. The sc* recordings also contain the submental-EMG envelope, oro-nasal airflow, rectal body temperature and an event marker, all sampled at 1 Hz. The st* recordings contain submental EMG sampled at 100 Hz and an event marker sampled at 1 Hz.
Hypnograms are manually scored according to Rechtschaffen & Kales based on Fpz-Cz / Pz-Oz EEG instead of C4-A1 / C3-A2 EEG: see
B van Sweden, B Kemp, HAC Kamphuisen, EA van der Velde. Alternative electrode placement in (automatic) sleep scoring (Fpz-Cz / Pz-Oz versus C4-A1 / C3-A2). Sleep 13(3):279-283 (1990).The sleep stages W, 1, 2, 3, 4, R, M and 'unscored' are coded in the file as binaries 0, 1, 2, 3, 4, 5, 6 and 9 according to Q16.3 of the EDF-FAQ.
The 4 sc* recordings were obtained in 1989 from ambulatory healthy volunteers during 24 hours in their normal daily life, using a modified cassette tape recorder. Subjects, recordings and hypnogram scoring are described in
MS Mourtazaev, B Kemp, AH Zwinderman, HAC Kamphuisen. Age and gender affect different characteristics of slow waves in the sleep EEG. Sleep 18(7):557-564 (1995).
The 4 st* recordings were obtained in 1994 from subjects who had mild difficulty falling asleep but were otherwise healthy, during a night in the hospital, using a miniature telemetry system with very good signal quality. Subjects and recordings are more extensively described in
B Kemp, AH Zwinderman, B Tuk, HAC Kamphuisen, JJL Oberyé. Analysis of a sleep-dependent neuronal feedback loop: the slow-wave microcontinuity of the EEG. IEEE-BME 47(9):1185-1194 (2000) [PDF].
Name Last modified Size Description
Parent Directory -
MD5SUMS 18-Sep-2007 10:36 840
RECORDS 08-Feb-2008 13:21 208 list of record names
SHA1SUMS 18-Sep-2007 10:36 1.0K
SHA256SUMS 18-Sep-2007 12:39 1.6K
sc4002e0.hyp 09-Dec-2002 13:35 6.0K EDF hypnogram
sc4002e0.rec 11-Sep-2007 07:40 49M EDF recording
sc4012e0.hyp 09-Dec-2002 15:45 6.1K EDF hypnogram
sc4012e0.rec 11-Sep-2007 07:42 50M EDF recording
sc4102e0.hyp 09-Dec-2002 16:17 6.1K EDF hypnogram
sc4102e0.rec 11-Sep-2007 07:46 50M EDF recording
sc4112e0.hyp 09-Dec-2002 15:49 5.9K EDF hypnogram
sc4112e0.rec 11-Sep-2007 07:47 48M EDF recording
st7022j0.hyp 09-Dec-2002 15:53 3.1K EDF hypnogram
st7022j0.rec 09-Dec-2002 15:51 31M EDF recording
st7052j0.hyp 09-Dec-2002 15:53 3.0K EDF hypnogram
st7052j0.rec 09-Dec-2002 14:36 30M EDF recording
st7121j0.hyp 09-Dec-2002 16:29 2.9K EDF hypnogram
st7121j0.rec 09-Dec-2002 14:43 29M EDF recording
st7132j0.hyp 09-Dec-2002 16:01 2.8K EDF hypnogram
st7132j0.rec 09-Dec-2002 14:44 27M EDF recording