STUDY ID: TRM259.RHC1 Device electrodes: 3M 2670 Indications: outpatient; heart failure; NYHA class III; EF 40% Clinical Score: compensated Physiological Score: compensated Sex: F Age: 37 Height (cm): 175.3 Weight (kg): 114.3 BP (mmHg): 117/65 Wearable #: 10 Wearable Placement: Below Jugular Notch Time difference: Wearable/PC 3:10:00 PM = MacLab 3:05:48 PM TEST 1: RHC PHASE: BASELINE (MacLab time) RA: 3:07:28 PM RV: 3:08:59 PM PA: 3:15:05 PM PCW: 3:13:56 PM SV (mL/beat): 91 Notes: h/o HFrEF 2/2 NICM, s/p ICD; PCW 1 min. measurement started slightly before timestamp