STUDY ID: TRM282.RHC1 Device electrodes: 3M 2670 Indications: outpatient; heart failure; NYHA class III; EF 43% Clinical Score: compensated Physiological Score: compensated Sex: M Age: 34 Height (cm): 170.2 Weight (kg): 62.4 BP (mmHg): 137/79 Wearable #: 10 Wearable Placement: Below Jugular Notch Time difference: Wearable/PC 1:36:03 PM = MacLab 1:40:00 PM TEST 1: RHC PHASE: BASELINE (MacLab time) RA: 1:43:45 PM RV: 1:50:19 PM PA: 1:41:37 PM PCW: 1:45:15 PM SV (mL/beat): 86 Notes: h/o HFrEF, NICM, PH, DM1