Database Open Access

Finger - PIP Database: Signals from Novel Biomedical FSR

,  ,  ,  ,  , 

Published Nov. 25, 2026 · Version 1.0.0
When using this resource, please cite:

Singh, R., Brandwood, B., Gargiulo, G., Gunawardana, U., Shirani, A., & Breen, P. (2026). Finger - PIP Database: Signals from Novel Biomedical FSR (version 1.0.0). PhysioNet. RRID:SCR_007345. https://doi.org/10.13026/fmh5-3812

Please include the standard citation for PhysioNet:

Pollard, T., Moody, B. E., Lehman, L., Gow, B., Fernandes, C., Xie, C., Johnson, A., Mark, R. G., & Heldt, T. (2026). PhysioNet as a global platform for biomedical research. Nature Health. https://doi.org/10.1038/s44360-026-00096-z. Available from: https://pmc.ncbi.nlm.nih.gov/articles/PMC13641116/

Abstract

A new dataset comprising signals from non-invasive biomedical sensors is used to compare the temporal performance of these sensors,including a novel hybrid sensor combining a force-sensing resistor (FSR) and a piezoelectric (PZT) sensor,as well as a photoplethysmography (PPG) sensor, and an electrocardiogram (ECG) sensor.The availability of such a dataset provides a repository for future researchers to study and develop multi-source biomedical models. The data recorded contains ECG, PPG, FSR, and PZT signals for each participant sampled at 10 kHz, which are typically between 1.5 and 12.5 minutes. Approach: The three sets of signals from 24 participants are recorded and processed. Results: The PZT sensor has a lower bandwidth than the FSR sensor but responds more quickly to changes in finger blood volume.The PPG reacts the slowest to blood volume changes in the finger, but is the least susceptible to noise among the three sensors. Significance: While the temporal attributes from the three sensors differ, these differences can be quantified and compensated using fixed phases,typically in a multi-source blood-estimation mode.


Background

Pulse transit time (PTT), pulse arrival time (PAT), and pulse wave velocity (PWV) are widely studied non-invasive biomarkers for cardiovascular assessment, with increasing relevance to wearable monitoring systems. PAT serves as a non-invasive marker for assessing acute changes in pre-ejection period during cardiac re-synchronization therapy and may help identify long-term treatment response [@villegasmartinez2023]. PTT enables cuff-less blood pressure estimation and correlates with invasive measures, supporting its use in continuous hemodynamic monitoring [@ding2019]. PWV provides an established indicator of arterial stiffness and cardiovascular risk, with surrogate measures such as PAT and PTT enabling practical implementation in wearable devices [@pal2024].

However, progress in algorithm development and validation is limited by availability of multimodal datasets capturing synchronized cardiovascular signals across varied sensing conditions. To address this, a multimodal dataset was collected from 24 participants in a clinical study conducted at Western Sydney University under ethics approval H15672. The dataset is intended to support research into wearable-based cardiovascular timing estimation and multimodal signal processing, with detailed study design, recording protocols, and sensor configurations described in the Methods section.


Methods

The database contains data from 24 participants that took part in the clinical trial conducted at Western Sydney University under research ethics approval H15672. Biomedical data were recorded using three ECG electrodes (Einthoven triangle configuration: left arm, right arm, left leg) and with a distal PPG sensor and a custom “morphic DOT” sensor (combined FSR–PZT) applied to one or two fingers. For each participant's recordings, between 3 and six multi-sensor recording configurations were made (FSRHFP1, FSRHFP2, FSRLFP1, FSRLFP2, LFPHFP1, LFPHFP2); 24 participants contributed 92 recordings with a median 3.5 recordings per participant. Four participants completed all configurations.

For each participant, up to six 5-minute recordings were obtained with different PZT hardware configurations and one finger or two finger placements: FSRHFP1, FSRHFP2 (high frequency PZT), FSRLFP1, FSRLFP2 (low frequency PZT), and LFPHFP1, LFPHFP2 (combined low and high frequency PZT). All signals (ECG, PPG, FSR, PZT) from each session are recorded simultaneously at 10 kHz using a BIOPAC MP36 data acquisition system and are stored in WFDB format as 32-bit data.

The raw signals acquired from the Biopac MP36 DAQ module are processed with notch filters in MATLAB, with centre frequencies ranging from 50 Hz to 150 Hz at 50 Hz intervals. Thereafter, the signals are low-pass filtered (LPF) at a cut-off frequency of 150 Hz to remove high-frequency noise.

Annotations for the ECG signal were obtained using the Pan- Tompkins algorithm, and the PPG, PZT and FSR waveform peak annotations were generated using a first derivitive detection using MATLAB findpeaks. Trough locations were generated using a local minimum search prior to peaks, and dicrotic notches were located using combined derivative and iterative envelope mean methodology. Signals were pre-processed using a Butterworth band pass filter with cutoff frequencies of 1 and 12 Hz.


Data Description

Each WFDB record contains four time aligned signals: a single-lead ECG, an infrared PPG from a distal finger probe, an FSR channel (distal contact force sensing of the finger), and a PZT channel (high frequency, low frequency, or combined, depending on the set). The morphic DOT board provides analogue conditioning and gain stages that give approximately 8.85× voltage gain for the recorded FSR channel and high and low frequency bands for the PZT channels.

The database is accompanied by per-beat annotations marking R-peak locations in the ECG signal and peak (systolic), trough (foot), and dicrotic notch positions in each of the three arterial blood pressure surrogate waveforms (PPG, FSR, PZT). The algorithm used to locate the provided fiducial points is the subject of a research article yet to be published [@brandwood2026]. Annotation types follow single-character codes compatible with WRANN: ECG R‑peaks use code ecg; PPG, FSR and PZT signals' peak, trough, and notch use P, V, and N respectively, following the ppg, fsr and pzt assignations. These fiducial labels enable direct computation and validation of PAT, PTT, PWV, and DN detection algorithms across all three modalities. From these annotations, per beat PAT from peaks (PATp), PAT from troughs/foots (PATf), and midpoint-based PTT can be calculated.

Within the PhysioNet project, WFDB signal files (.dat) and header files (.hea) are organised by subject and recording condition, with record names encoding participant index and set (for example, TXX_FSRHFP1). For each record, corresponding annotation files (.ecg, .ppgP/.ppgT/.ppgN, .pztP/.pztT/.pztN, .fsrP/.fsrT/.fsrN) store the fiducial markers defined above. The ANNOTATORS file describes the annotation types for each annotation file. A separate technical report describes the hardware and pre-processing methods [@singh2026].

The subject-info.csv file provides per-participant metadata, including an integer participant identifier (linking to waveform records T01–T24), gender, age, and a set of columns indicating whether each recording configuration (FSRHFP1, FSRHFP2, FSRLFP1, FSRLFP2, LFPHFP1, LFPHFP2) is present for that subject. A special value "ü" in a configuration column denotes that a recording for that configuration was obtained and is included in the dataset for that participant, while a "-" indicates that the corresponding signal configuration was not recorded for that subject and therefore no waveform record exists for it.


Usage Notes

These data are intended for research on pulse wave analysis, sensor fusion, non-optical alternatives< for PPG, fiducial point detection, and DN detection. Users should cite the associated technical report and any subsequent journal articles describing the finger PIP / morphic DOT dataset and algorithms. No special software is required to access the database.

The cohort includes 24 participants, which provides a focused sample and does not represent population‑level inference and comprehensive subject variability in pulse morphology, PAT/PTT, or sensor performance. In addition, each configuration is recorded over relatively short intervals (approximately 5‑minute segments), so the database does not capture longer‑term trends, diurnal variability, or the influence of extended activities and posture changes. Finally, not all participants completed all six intended configurations (FSRHFP1, FSRHFP2, FSRLFP1, FSRLFP2, LFPHFP1, LFPHFP2), meaning some configurations will be based on smaller subsets of subjects.


Release Notes

Version 1.0.0:

Initial public release of the dataset.


Ethics

This study involves minimal risk physiological monitoring of healthy adult volunteers and was conducted under institutional ethics approval, with appropriate consent and data handling safeguards in place.

Data collection was performed in a study at Western Sydney University under human research ethics approval H15672, ensuring formal review of risk, consent, and data protection procedures. All participants were healthy adults who gave informed written consent prior to recording electrocardiogram (ECG), photoplethysmography (PPG), force-sensitive resistor (FSR), and piezoelectric (PZT) signals at the finger for research on pulse arrival time, pulse transit time, pulse wave velocity, and dicrotic notch detection.

Benefits:

The database enables development and validation of algorithms for pulse wave analysis, sensor fusion, dicrotic notch detection, and non-optical alternatives to PPG, supporting advances in cardiovascular monitoring and digital health technologies.

Risks:

Risks to participants were primarily related to non-invasive sensor application (finger probes, surface electrodes) and brief experimental burden, which are considered minimal in standard biomedical monitoring studies. Identifiable information is not included in the shared WFDB records, which contain only de-identified physiological waveforms and derived annotations, reducing risks related to privacy or data misuse.

The database is intended for research and methodological development in pulse wave analysis and related fields, and users are expected to cite the accompanying technical report and publications to maintain transparency and credit. Database users should comply with their own institution's ethical standards and data governance policies when analysing or redistributing results from this database.


Conflicts of Interest

Benjamin Brandwood reports financial support was provided by Medical Monitoring Solutions. Paul Breen reports a relationship with Medical Monitoring Solutions that includes: equity or stocks and funding grants. Gaetano Gargiulo reports a relationship with Medical Monitoring Solutions that includes: equity or stocks and funding grants. Benjamin Brandwood reports a relationship with Medical Monitoring Solutions that includes: funding grants. Gaetano Gargiulo has patent #10182727 Monitoring pneumocardial function issued to G Gargiulo, P Breen. Financial support was provided by Medical Monitoring Solutions through the NSSN grant partially sponsored by Medical Monitoring Solutions. BB completed an unpaid internship with Medical Monitoring Solutions. Coauthors are listed as inventors on the patent Monitoring pneumocardial function, and are minority shareholders of Medical Monitoring Solutions Pty Ltd that has licensed the aforementioned patent. If there are other authors, they declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. Ram Singh reports no competing interest.


References

  1. @villegasmartinez2023 Villegas-Martinez, M., Odland, H.H., Hammersbøen, L.-E., Sletten, O.J., Stugaard, M., Witsø, M., Khan, F., Wajdan, A., Elle, O.J. and Remme, E.W., 2023. Pulse arrival time variation as a non-invasive marker of acute response to cardiac resynchronization therapy. EP Europace, 25(3), pp.1183–1192. doi:10.1093/europace/euad013.
  2. @ding2019 Ding, X. and Zhang, Y.T., 2019. Pulse transit time technique for cuffless unobtrusive blood pressure measurement: from theory to algorithm. Biomedical Engineering Letters, 9(1), pp.37–52. doi:10.1007/s13534-019-00096-x.
  3. @pal2024 Pal, R., Rudas, A., Kim, S., Chiang, J.N., Braney, A. and Cannesson, M., 2024. An algorithm to detect dicrotic notch in arterial blood pressure and photoplethysmography waveforms using the iterative envelope mean method. Computer Methods and Programs in Biomedicine, 254, p.108283. doi:10.1016/j.cmpb.2024.108283.
  4. @brandwood2026 Brandwood, B., Gargiulo, G.D., Breen, P., Gunawardana, U. and Singh, R., 2026. A Benchmark Resource for Dicrotic Notch Detection in Photoplethysmography. doi:10.13140/RG.2.2.20225.01121.
  5. @singh2026 Singh, R., Brandwood, B., Shirani, A., Gunawardana, U., Breen, P. and Gargiulo, G., 2026. Finger-PIP Database: Evaluating Feasibility of Piezoresistive and Piezoelectric Sensors as Alternatives to PPG for Pulse Monitoring. doi:10.13140/RG.2.2.17132.12162.

Files

Total uncompressed size: 3.8 GB.

Access the files

Visualize waveforms

Folder Navigation: <base>/Ethics_Consent_Data
Name Size Modified
Parent Directory
H15672-1.PDF (download) 42.7 KB 2026-07-28
H15672-2.PDF (download) 1.4 MB 2026-07-28