Long Term ST Database 1.0.0
(4,304 bytes)
ST ANNOTATIONS IN THE RECORD s20121 (Duration: 21:21:44.000)
Starting time, recording date: 09:21:00 30/01/1995
Lead 0: ML2
Lead 1:
A. Criteria of 30 seconds and 75 microVolts (s20121.sta)
Lead 0:
Ischemic episodes: 9 Duration: 1:11:22 5.57%
Rate-related episodes: 0 Duration: 0:00 0.00%
Axis shifts: 15
Conduction-change shifts: 0
Noisy events: 0
Unreadable intervals: 0 Duration: 0:00 0.00%
Lead 1:
Ischemic episodes: 0 Duration: 0:00 0.00%
Rate-related episodes: 0 Duration: 0:00 0.00%
Axis shifts: 8
Conduction-change shifts: 0
Noisy events: 1
Unreadable intervals: 0 Duration: 0:00 0.00%
Total:
Ischemic episodes: 9 Duration: 1:11:22 2.78%
Rate-related episodes: 0 Duration: 0:00 0.00%
Axis shifts: 23
Conduction-change shifts: 0
Noisy events: 1
Unreadable intervals: 0 Duration: 0:00 0.00%
Combined:
Ischemic episodes: 9 Duration: 1:11:22 5.57%
Rate-related episodes: 0 Duration: 0:00 0.00%
Unreadable intervals: 0 Duration: 0:00 0.00%
Combined [ischemic or rate-related]:
ST segment episodes: 9 Duration: 1:11:22 5.57%
Unreadable intervals: 0 Duration: 0:00 0.00%
B. Criteria of 30 seconds and 100 microVolts (s20121.stb)
Lead 0:
Ischemic episodes: 2 Duration: 17:32 1.37%
Rate-related episodes: 0 Duration: 0:00 0.00%
Axis shifts: 15
Conduction-change shifts: 0
Noisy events: 0
Unreadable intervals: 0 Duration: 0:00 0.00%
Lead 1:
Ischemic episodes: 0 Duration: 0:00 0.00%
Rate-related episodes: 0 Duration: 0:00 0.00%
Axis shifts: 8
Conduction-change shifts: 0
Noisy events: 1
Unreadable intervals: 0 Duration: 0:00 0.00%
Total:
Ischemic episodes: 2 Duration: 17:32 0.68%
Rate-related episodes: 0 Duration: 0:00 0.00%
Axis shifts: 23
Conduction-change shifts: 0
Noisy events: 1
Unreadable intervals: 0 Duration: 0:00 0.00%
Combined:
Ischemic episodes: 2 Duration: 17:32 1.37%
Rate-related episodes: 0 Duration: 0:00 0.00%
Unreadable intervals: 0 Duration: 0:00 0.00%
Combined [ischemic or rate-related]:
ST segment episodes: 2 Duration: 17:32 1.37%
Unreadable intervals: 0 Duration: 0:00 0.00%
C. Criteria of 60 seconds and 100 microVolts (s20121.stc)
Lead 0:
Ischemic episodes: 1 Duration: 13:40 1.07%
Rate-related episodes: 0 Duration: 0:00 0.00%
Axis shifts: 15
Conduction-change shifts: 0
Noisy events: 0
Unreadable intervals: 0 Duration: 0:00 0.00%
Lead 1:
Ischemic episodes: 0 Duration: 0:00 0.00%
Rate-related episodes: 0 Duration: 0:00 0.00%
Axis shifts: 8
Conduction-change shifts: 0
Noisy events: 1
Unreadable intervals: 0 Duration: 0:00 0.00%
Total:
Ischemic episodes: 1 Duration: 13:40 0.53%
Rate-related episodes: 0 Duration: 0:00 0.00%
Axis shifts: 23
Conduction-change shifts: 0
Noisy events: 1
Unreadable intervals: 0 Duration: 0:00 0.00%
Combined:
Ischemic episodes: 1 Duration: 13:40 1.07%
Rate-related episodes: 0 Duration: 0:00 0.00%
Unreadable intervals: 0 Duration: 0:00 0.00%
Combined [ischemic or rate-related]:
ST segment episodes: 1 Duration: 13:40 1.07%
Unreadable intervals: 0 Duration: 0:00 0.00%
QRS ATRUTH ANNOTATIONS (s20121.atr)
Total number of beats 85526
Normal beats 84927
Premature ventricular contractions 580
Supraventricular premature or ectopic beats 19