Myocardial perfusion scintigraphy image database 1.0.0
(3,532 bytes)
# Data_Description.txt
The following content describes the structure, metadata, and clinical annotations (or lack thereof) associated with the dataset, as required in the Data Description section of the PhysioNet submission.
### Data Description
This dataset contains myocardial perfusion scintigraphy (MPS) images from 83 unique patients, acquired using a CZT-based gamma camera (Discovery NM 530c, GE Healthcare). All images were obtained under rest-only protocols using a standardized one-day acquisition procedure with 99mTc-MIBI. The dataset is anonymized and includes two image formats: DICOM (original input) and NIfTI (preprocessed volumes and segmentation masks, when available).
### Metadata
Basic demographic metadata are provided in a CSV file named demographics.csv, which includes the following columns:
patient_id (pseudonymized and matching image folder IDs)
sex (M/F)
age (in years)
BMI (when available)
Each row corresponds to a single study and is linked to the image files by the patient_id. No personally identifiable information is included. These demographic attributes were extracted from REDCap records and harmonized with anonymized DICOM tags.
In addition to demographic information, technical metadata were extracted from DICOM headers and are consistent across all studies in the dataset. The acquisition protocol is standardized. A representative exam is used to illustrate the typical metadata fields found across all studies:
Modality: NM (Nuclear Medicine)
Manufacturer: GE Medical Systems
Scanner model: Discovery NM 530c
Collimator type: Pinhole (MPH_27_45)
Radiopharmaceutical: 99mTc-MIBI
Energy window: 126.45–154.55 keV
Patient position: Supine, feet-first
Image resolution: 70×70 pixels, with 4.0×4.0 mm² pixel spacing
Slice thickness: 4.0 mm, 50 slices per volume
Photometric interpretation: MONOCHROME2
Bit depth: 16-bit (Bits Allocated: 16; Pixel Representation: signed)
Window center/width: 16383 / 32767
Spatial resolution: 5 mm (as reported)
Software version: VNA-NORMATIZADOR v0.1.0
Deidentification protocol: Basic Application Confidentiality Profile (DICOM codes 113100, 113101, 113107)
These metadata specifications are identical across all 101 studies and their corresponding 103 DICOM images. The discrepancy between the number of DICOM and NIfTI files arises because two studies were not segmented, resulting in 101 NIfTI volumes (with masks) and 103 original DICOM files. All NIfTI files were generated directly from the DICOM images using a standardized preprocessing pipeline.
Clinical reports are not included, in accordance with anonymity protocols and institutional constraints. A Python script (`extract_dicom_metadata.py`) is provided for reproducibility and further exploration. The current `demographics.csv` file was generated from a single representative DICOM exam using this script. All other exams follow an identical DICOM structure and acquisition protocol, ensuring consistency across the dataset.
### Descriptive Statistics
Total studies: 83
Sex distribution: 88% male, 12% female
Age range: 20 to 90 years
Diagnosis labels: Not provided
Confirmed ischemia/necrosis: Not labeled or quantified in this release
This dataset is intended to support research in segmentation and preprocessing techniques in nuclear cardiology. Future releases may include artifact annotations or diagnostic labels, pending ethical approval and enhanced anonymization protocols.