Myocardial perfusion scintigraphy image database 1.0.0

File: <base>/data_description.txt (3,532 bytes)
# Data_Description.txt

The following content describes the structure, metadata, and clinical annotations (or lack thereof) associated with the dataset, as required in the Data Description section of the PhysioNet submission.

### Data Description
This dataset contains myocardial perfusion scintigraphy (MPS) images from 83 unique patients, acquired using a CZT-based gamma camera (Discovery NM 530c, GE Healthcare). All images were obtained under rest-only protocols using a standardized one-day acquisition procedure with 99mTc-MIBI. The dataset is anonymized and includes two image formats: DICOM (original input) and NIfTI (preprocessed volumes and segmentation masks, when available).

### Metadata
Basic demographic metadata are provided in a CSV file named demographics.csv, which includes the following columns:

patient_id (pseudonymized and matching image folder IDs)

sex (M/F)

age (in years)

BMI (when available)

Each row corresponds to a single study and is linked to the image files by the patient_id. No personally identifiable information is included. These demographic attributes were extracted from REDCap records and harmonized with anonymized DICOM tags.

In addition to demographic information, technical metadata were extracted from DICOM headers and are consistent across all studies in the dataset. The acquisition protocol is standardized. A representative exam is used to illustrate the typical metadata fields found across all studies:

Modality: NM (Nuclear Medicine)

Manufacturer: GE Medical Systems

Scanner model: Discovery NM 530c

Collimator type: Pinhole (MPH_27_45)

Radiopharmaceutical: 99mTc-MIBI

Energy window: 126.45–154.55 keV

Patient position: Supine, feet-first

Image resolution: 70×70 pixels, with 4.0×4.0 mm² pixel spacing

Slice thickness: 4.0 mm, 50 slices per volume

Photometric interpretation: MONOCHROME2

Bit depth: 16-bit (Bits Allocated: 16; Pixel Representation: signed)

Window center/width: 16383 / 32767

Spatial resolution: 5 mm (as reported)

Software version: VNA-NORMATIZADOR v0.1.0

Deidentification protocol: Basic Application Confidentiality Profile (DICOM codes 113100, 113101, 113107)

These metadata specifications are identical across all 101 studies and their corresponding 103 DICOM images. The discrepancy between the number of DICOM and NIfTI files arises because two studies were not segmented, resulting in 101 NIfTI volumes (with masks) and 103 original DICOM files. All NIfTI files were generated directly from the DICOM images using a standardized preprocessing pipeline.

Clinical reports are not included, in accordance with anonymity protocols and institutional constraints. A Python script (`extract_dicom_metadata.py`) is provided for reproducibility and further exploration. The current `demographics.csv` file was generated from a single representative DICOM exam using this script. All other exams follow an identical DICOM structure and acquisition protocol, ensuring consistency across the dataset.


### Descriptive Statistics
Total studies: 83

Sex distribution: 88% male, 12% female

Age range: 20 to 90 years

Diagnosis labels: Not provided

Confirmed ischemia/necrosis: Not labeled or quantified in this release

This dataset is intended to support research in segmentation and preprocessing techniques in nuclear cardiology. Future releases may include artifact annotations or diagnostic labels, pending ethical approval and enhanced anonymization protocols.