SCG-RHC: Wearable Seismocardiogram Signal and Right Heart Catheter Database 1.0.0

File: <base>/raw_data/annotations/TRM145.RHC1.txt (735 bytes)
SUBJECT ID: TRM145.RHC1
Device electrodes: 3M 2670 

Indications: outpatient; heart failure; compensated; NYHA class III; EF 51%

Sex: F
Age: 50
Height (cm): 157.5
Weight (kg): 74.5
BP (mmHg): 120/67

Wearable Placement: Below Jugular Notch

Time difference: Wearable/PC 11:47:00 AM = MacLab 11:40:30 AM

TEST 1: RHC

PHASE: BASELINE 
(MacLab time)
RA: 11:37:41 AM
RV: 11:48:41 AM
PA: 12:01:05 PM; 12:08:33 PM; 12:14:13 PM  
PCW: 12:07:57 PM
SV (mL/beat): 77


TEST 2: LHC

PHASE: BASELINE
(MacLab Time)
[Sys/Dias/EDP/HR]

LV: 12:20:07 PM 
[135/-1/4/75]

LV: 12:20:27 PM
[134/-3/3/75]

LV: 12:20:41 PM
[138/-1/4/75]

Notes: h/o HFrEF, D-TGA s/p Blalock Hanlon & Mustard procedure, SSS s/p PM, aflutter s/p ablation, s/p atrial switch