SCG-RHC: Wearable Seismocardiogram Signal and Right Heart Catheter Database 1.0.0

File: <base>/raw_data/annotations/TRM243.RHC1.txt (686 bytes)
STUDY ID: TRM243.RHC1
Device electrodes: 3M 2670 

Indications: outpatient; heart failure; NYHA class II; EF 16%
Clinical Score: compensated
Physiological Score: decompensated

Sex: F
Age: 63
Height (cm): 157.5
Weight (kg): 55.8
BP (mmHg): 108/70

Wearable #: 18

Wearable Placement: Below Jugular Notch

Time difference: Wearable/PC 3:41:20 PM = MacLab 3:41:19 PM

TEST 1: RHC

PHASE: BASELINE 
(MacLab time)
RA: 3:47:02 PM
RV: 3:50:02 PM
PA: 3:51:44 PM
PCW: 3:53:30 PM
SV (mL/beat): 37

PHASE: S/P Nitro - Nitroglycerin SL 800 mcg
(MacLab time)
RA: 4:08:32 PM
RV: nd
PA: 4:10:30 PM
PCW: 4:12:16 PM
SV (mL/beat): 37

Notes: h/o HFrEF, NICM 2/2 peripartum CM s/p ICD, pAF/fluttter, VT