Classification of Heart Sound Recordings: The PhysioNet/Computing in Cardiology Challenge 2016 1.0.0

File: <base>/annotations/hand_corrected/readme.txt (586 bytes)
Segmentation annotations with hand-corrected for PhysioNet/CinC Challenge 2016.
Four states were annotated in the file: S1, systole, S2 and diastole. 

each file has two columns: 

***************************************
column 1: start point  of each state
column 2: state name (S1, systole, S2 and diastole in turn)

the noisy signal segment is annotated as: '(N' for start point and 'N)' for end point
Sample rate: 2,000 Hz
***************************************


 
--
Chengyu Liu
chengyu.liu@emory.edu